Product characteristics
High sensitivity (better than 10-6 emu/rt-Hz);
Table type, small size;
Simple measurement, fast and friendly interface:
Magnetic instrument innovative collocationreduce human operation and calculation time;
The temperature range is continuously adjustablefrom room temperature to 900 K:
Product introduction
LSVM-1500 vibrating magnetometer: It is a highly sensitive magnetic measurement tool, which can measurethe magnetic parameters of various materials, Combined with the analysis software with automatic calculationand analvsis function, it can quickly obtain various maanetic related parameters of samples (such asmagnetization curve, hysteresis loop, demagnetization curve, saturation magnetization, residual magnetizationetc.) from the original measurement signal.
Pumose: it can make the sample in the uniform maanetic field rapid vibration, the sample in the process ofmagnetization and demagnetization phenomenon, we take this analysis, we can get the magnetization curve ofthe sample, for the next study;
Main specifications: Maximum magnetic field 0.8T, temperature range of 80K-1000K
Applicable sample size: the size is in the range of 10mmx10mmx10mm;
Applicable sample form: suitable for flake (i.e., film), powder sample measurement;
Applications: Detection of magnetic MEMS; Random access memory, Spintronic sensor and biosensor
Specification parameter
Project |
Content |
Measurement mode |
Vibration method to achieve automatic measurement |
Measurement accuracy |
103emu-100 emu |
Measuring function |
Measurement at high temperature, low temperature and room temperature |
Measurement error |
<2% |
Size |
Measuring system: 79 cm*49 cm*131 cm; |
Temperature control system: 52 cm *81 cm *155 cm; |
Control cabinet:146 cm *42 cm *82 cm |
Product specification parameter :(LSVM-1500 )
1.Magnetic field system
1-1. Electromagnet (when the air gap is less than 30mm, the magnetic field strenath can reach 0.8T)
1-2. Power supply (1500 Watts)
1-3. Built-in Gauss meter (Measuring range: 30k Gauss to 1Gauss)
1-4. Measurement of built-in magnetic flux
2.Vibrating sample system
2-1.Vibrating equipment
2-2.Sample carrier
3.control system
3-1. Buiit-in Computer (with Microsoft operating system)
3-2. Built-in software interface, easy to operate and perform datameasurement and analysis(It can automatically measure the hysteresis loop, automatically findout the saturation magnetization, coercive field, remanence andother parameters of the material, and also automatically implementand measure the demaqnetization process.)
3-3. Built in high precision data measurement system
4.other
4-1. Liquid crystal display
4-2. Keyboard and mouse
Apply case or test data
The device passes direct current to the electromagnetthrough the Dc power supply to generate uniformand stable magnetic field,thus magnetizing thesample in the center of the pole head. Using thesignal amplifier, the natural frequency of the shaker a37HZ drives the sample to vibrate, making the samplemove to cut the maqnetic sensing line, qenerating theinduced electromotive force to be read by the lock-inamplifier so as to complete the measurement.Can be used to measure solid,liquid,powder qranularsamples.
Company Profile
Resound Photoelectric Technology Research Institute (LSRPTR)
Resound Photoelectric Technology Research Institute (LSRPTR), also known as Resound Research Institute, is affiliated with China Haiheng International Trade Group Co., Ltd. (CHHGC). As an investment attraction enterprise in Zhongyuan Science and Technology City and a construction unit of the Zhongyuan Aurora Laboratory, the institute is committed to the industrialization of scientific and technological achievements, guided by market demand.
Technical Cooperation
Resound Research Institute has established technical cooperation with numerous well-known domestic and foreign universities, research institutes, and enterprise platforms, including:
Tsinghua University
Lanzhou University
Zhengzhou University
Altai State Technical University of Russia
Northwestern Polytechnical University
Chinese Academy of Engineering
Henan Academy of Sciences
China Electronics Technology Group
CGN Group
Xiamen University
Henan University
National University
University of Electronic Science and Technology of China
Chinese Academy of Sciences
China Academy of Engineering Physics
China Shipbuilding Group
China Electronics Group
Henan Inspection Group
Research and Development Fields
* Applications of Micro-Electromechanical and Lithography Technology
* Optoelectronics and Spectroscopy Technology
* High-Power Laser and Device Preparation Technology
* Nuclear Instrument and Emergency Equipment System Applications
Introducing Advanced Technologies and Products
Resound Research Institute continuously introduces advanced new technologies and products in industrial application scenarios such as market supervision, public safety, environmental monitoring, and science, education, research, and production. This has led to the formation of a domestically produced high-end scientific equipment industry base that integrates design, research and
development, production, sales, and services. This base drives the iteration of downstream industry technology, enhances the transformation and industrialization level of scientific and technological achievements, and provides technological sources for innovative development.