2025 Lspec 7100 Online Turbidity Analyzer

Product Details
Customization: Available
After-sales Service: 1 Year
Detection Principle: 90° Light Scattering Method

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Fast Delivery
The supplier can deliver the goods within 15 days
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (13)
  • 2025 Lspec 7100 Online Turbidity Analyzer
  • 2025 Lspec 7100 Online Turbidity Analyzer
  • 2025 Lspec 7100 Online Turbidity Analyzer
  • 2025 Lspec 7100 Online Turbidity Analyzer
  • 2025 Lspec 7100 Online Turbidity Analyzer
  • 2025 Lspec 7100 Online Turbidity Analyzer
Find Similar Products
  • Overview
  • Detailed Photos
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
LSPEC 7100
Detection Range
0.0000 to 99.9999 Ntu
Detection Accuracy
0-40 Ntu: ±2% or ±0.02 (Whichev
Repeatability
Better Than ±1% of Reading
Resolution
0.0001 Ntu
Signal Averaging
Options: None, 6, 30, 60, 90
Power Requirements
24V DC
Operating Temperature
0ºC to 45ºC
Sample Temperature
0ºC to 40ºC
Sample Flow Rate
200 to 750 Ml/Min
Protection Level
IP64
Calibration Method
Stable Formaldehyde
Digital Communication
RS485, Standard Modbus Proto
Inlet Connection
NPT 1/4 Internal Thread
Outlet Connection
NPT 1/2 Internal Thread
Transport Package
Wooden Box
Specification
230*226*450mm
Trademark
Resound
Origin
China

Product Description

Detailed Photos

2025 Lspec 7100 Online Turbidity Analyzer2025 Lspec 7100 Online Turbidity Analyzer

2025 Lspec 7100 Online Turbidity Analyzer2025 Lspec 7100 Online Turbidity Analyzer2025 Lspec 7100 Online Turbidity Analyzer2025 Lspec 7100 Online Turbidity Analyzer
Product Parameters

Product Introduction
The LSPEC 7100 Online Turbidity Analyzer utilizes the 90-degree light scattering method. It employs a highly stable tungsten lamp as the light source, which is collimated into parallel light through a lens. This light enters the turbidity analyzer vertically and interacts with a sensor submerged in the water. The sensor detects the light scattered at a 90° angle after passing through the suspended particles in the water. The turbidity monitoring and analysis are achieved through linear fitting of the light intensity to the turbidity values of the water sample.
Features

  1. Built-in Continuous Flow Bubble Elimination Structure: Eliminates bubbles in the water sample, ensuring stable water flow in the detection area and reducing interference from bubbles and flow fluctuations.
  2. 90° Scatter Light Reception Design: This design minimizes interference from stray light and secondary scattering, with 90° scattered light having minimal impact from particle size variations, thus providing good linearity in low turbidity detection.
  3. Tungsten Lamp Light Source: Utilizes visible light, which is approximately 9 times more sensitive to scattering than infrared light, leading to higher detection sensitivity.
  4. Compatible with ALPHAPEC 700 Control Terminal: Offers integrated control and display capabilities for enhanced user interaction.
  5. Simple Calibration Operation: Calibration can be easily performed with a formaldehyde solution, guided by a visual calibration program. Two-point calibration at 0 and 20 NTU is recommended, with the option for custom calibration between 0 and 40 NTU.
  6. Hydrostatic Sampling and Optional Peristaltic Pump Sampling: Allows for flexible sampling methods to suit various operational needs.
  7. User-Defined Sampling Intervals: Users can set sampling intervals to prolong the instrument's lifespan.
  8. Concentration Alarm Function: The instrument is equipped with a concentration alarm feature, allowing users to set threshold values for alerts.
Parameters
Item Technical Specification
Detection Principle 90° light scattering method
Detection Range 0.0000 to 99.9999 NTU
Detection Accuracy 0-40 NTU: ±2% or ±0.02 (whichever is greater); 40-100 NTU: ±5%
Repeatability Better than ±1% of reading
Resolution 0.0001 NTU
Signal Averaging Options: None, 6, 30, 60, 90
Power Requirements 24V DC
Operating Temperature 0ºC to 45ºC
Sample Temperature 0ºC to 40ºC
Sample Flow Rate 200 to 750 ml/min
Protection Level IP64
Calibration Method Stable formaldehyde
Digital Communication RS485, standard MODBUS protocol
Inlet Connection NPT 1/4 internal thread
Outlet Connection NPT 1/2 internal thread
Communication Cable Default: 1.5 m (customizable)
Dimensions 230 mm × 226 mm × 450 mm
Installation Method Wall-mounted installation
Sampling Pump Peristaltic pump (optional)
 

Technical Principle

The turbidity measurement methods are primarily divided into transmission turbidity method and scattering turbidity method. The transmission method has a simple structure, but the changes in transmitted light caused by slight turbidity variations are minimal, leading to low sensitivity. This method requires a very high detector resolution and is not suitable for low turbidity detection. In contrast, the scattering turbidity method offers higher precision and sensitivity for low turbidity measurements.
When a light beam of a specific wavelength enters a water sample, turbidity substances in the sample cause the light to scatter. At low turbidity levels, the intensity of scattered light has a linear relationship with the turbidity of the water sample. By measuring the intensity of scattered light at a direction perpendicular to the incident light, the turbidity of the water sample can be determined. Using 90° scattering detection avoids multiple scattering phenomena and is least sensitive to particle shape, thereby improving measurement accuracy.

Application Areas

Monitoring turbidity before and after filtration, during sedimentation, and in the final output water at drinking water treatment plants; quality monitoring of circulating cooling water and effluent from activated carbon filters in industrial processes; water quality monitoring in municipal pipeline networks; and monitoring the quality of water in regional secondary supply systems.
 

Company Profile
Resound Photoelectric Technology Research Institute (LSRPTR)

Resound Photoelectric Technology Research Institute (LSRPTR), also known as Resound Research Institute, is affiliated with China Haiheng International Trade Group Co., Ltd. (CHHGC). As an investment attraction enterprise in Zhongyuan Science and Technology City and a construction unit of the Zhongyuan Aurora Laboratory, the institute is committed to the industrialization of scientific and technological achievements, guided by market demand.

 

Technical Cooperation

Resound Research Institute has established technical cooperation with numerous well-known domestic and foreign universities, research institutes, and enterprise platforms, including:
 
Tsinghua University
Lanzhou University
Zhengzhou University
Altai State Technical University of Russia
Northwestern Polytechnical University
Chinese Academy of Engineering
Henan Academy of Sciences
China Electronics Technology Group
CGN Group
Xiamen University
Henan University
National University
University of Electronic Science and Technology of China
Chinese Academy of Sciences
China Academy of Engineering Physics
China Shipbuilding Group
China Electronics Group
Henan Inspection Group
 

Research and Development Fields

* Applications of Micro-Electromechanical and Lithography Technology
* Optoelectronics and Spectroscopy Technology
* High-Power Laser and Device Preparation Technology
* Nuclear Instrument and Emergency Equipment System Applications

 

Introducing Advanced Technologies and Products

Resound Research Institute continuously introduces advanced new technologies and products in industrial application scenarios such as market supervision, public safety, environmental monitoring, and science, education, research, and production. This has led to the formation of a domestically produced high-end scientific equipment industry base that integrates design, research and
development, production, sales, and services. This base drives the iteration of downstream industry technology, enhances the transformation and industrialization level of scientific and technological achievements, and provides technological sources for innovative development.


2025 Lspec 7100 Online Turbidity Analyzer2025 Lspec 7100 Online Turbidity Analyzer2025 Lspec 7100 Online Turbidity Analyzer2025 Lspec 7100 Online Turbidity Analyzer2025 Lspec 7100 Online Turbidity Analyzer2025 Lspec 7100 Online Turbidity Analyzer2025 Lspec 7100 Online Turbidity Analyzer2025 Lspec 7100 Online Turbidity Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now