Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512

Product Details
Customization: Available
After-sales Service: 1 Year
Application: Industrial
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Fast Delivery
The supplier can deliver the goods within 15 days
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (13)
  • Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512
  • Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512
  • Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512
  • Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512
  • Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512
  • Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512
Find Similar Products

Basic Info.

Model NO.
ATH3010-17
Warranty
1 Year
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Rotary
Wavelengths
Visible Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Polychromator
Certification
RoHS, ISO9001, CE
Customized
Non-Customized
Spectral Range
900-1700nm
Spectral Resolution
1.3 Nm
Sampling Interval
0.37nm
F-Number
F/2.6
Detector
CMOS
Detector Interface
USB3.0
Supply Power
USB Powered, 3.4W
Detector Target Size
11.26mm X 5.98mm
Transport Package
Box
Specification
306 mm x 300 mm x 162mm
Trademark
optosky
Origin
China
HS Code
9011
Production Capacity
10000

Product Description

Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512Rotary Scan Hyperspectral Imaging System ATH3010

Description
ATH3010 is a miniature hyperspectral imager withsmall size and light weight. In addition to small size and light weight, the ATH3010 has the characteristics of high spatial resolution, highspectral resolution and wide imaging range. ATH3010 at the same time built-in high stability high blue lightingsource, and the power is adjustable, no additional light source. The ATH3010 is composed of two parts: hyperspectral imager and automatic electric rotary table. The highspectral instrument is based on high efficiencytransmission grating technology and has good aberrationcharacteristics. The ATH3010 can also be installed on a tripod or pole, andadd automatic calibration device, weather monitoringsensor, etc., so as to achieve a long time, large area scanof the target.

Features
High sensitivity hyperspectral imager
13 megapixel visible light camera, spectral integration;
High-performance image sensor, extremely cost-effective
High stability high blue lighting source, power adjustable
Full target surface high imaging quality optical design, point row spot diameter less than 0.5 pixel
The objective lens interface is standard C-Mount, and the objective lens can be replaced according to user requirements
Band range: 400-1000nm
Hyperspectral resolution: 1.3 nm
Maximum Angle of view: 31.7°
Minimum instantaneous field of view
Angle: 1.2 mrad
Excellent imaging performance


Application
Agricultural application: pest monitoring, nutrient monitoring, disaster assessment, crop yield estimation, etc
Forestry: Tree categories identification, Phytomass, nutrient elements, forest health etc.
Water Environment: Water quality parameters, water waste spatial distribution and migration analysis
Soil pollution: heavy metal waste
Minerals: Mineral mapping, ingredients explore, metallogenic prognosis etc.
City : Urban planning, road monitoring, landscape vegetation monitoring, environmental protection
Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512
| Items                                    | ATH3010          | ATH3010-4        |
|------------------------------------------|------------------|------------------|
| Spectral Range                           | 400-1000nm       | 400-1000nm       |
| Spectral Resolution                      | 1.3 nm           | 1.3 nm           |
| Sampling Interval                        | 0.37nm           | 0.37nm           |
| F-number                                 | F/2.6            | F/2.6            |
| Detector                                 | CMOS             | CMOS             |
| Detector Interface                       | USB3.0           | USB3.0           |
| Supply Power                             | USB powered, 3.4W | USB powered, 3.3W |
| Detector Target Size                     | 11.26mm × 5.98mm | 11.26mm × 11.26mm |
| Detector Original Resolution             | 2048 × 1088      | 2048 × 2048      |
| Detector Original pixel size             | 5.5 µm × 5.5 µm  | 5.5 µm × 5.5 µm  |
| Bit Depth                                | 12 bits          | 12 bits          |
| Slit Width                               | 25 µm            | 25 µm            |
| Recommended Way To Merge Cells           | 4×4 or 2×4       | 4×4 or 2×4       |
| Spatial dimension effective pixel number | 512 or 1024      | 512 or 1024      |
| Spectral band number                     | 272 or 544       | 512 or 1024      |
| Angle of view (FOV)                      | 15.2°@f=35mm     | 15.2°@f=35mm     |
| Instantaneous Field of view (IFOV)       | 0.7mrad@f=35mm   | 0.7mrad@f=35mm   |
| Maximum frame frequency                  | 340 fps          | 140 fps          |
| Size                                     | 306 mm × 300 mm × 162mm | 306 mm × 300 mm × 162mm |
| Weight                                   | less than 5.5 Kg      | less than 5.5 Kg      |
| Operating temperature                    | -10 - 50ºC        | -10 - 50ºC        |
| Storage temperature                      | -30-70ºC         | -30-70ºC         |
| Number of spectral channels              | ≥1024 (2× pixel merge mode) | ≥1024 (2× pixel merge mode) |
| The number of spatial channels           | ≥512 (2× pixel merge mode)  | ≥1024 (2× pixel merge mode)  |
Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512
Resound Photoelectric Technology Research Institute (LSRPTR)

Resound Photoelectric Technology Research Institute (LSRPTR), also known as Resound Research Institute, is affiliated with China Haiheng International Trade Group Co., Ltd. (CHHGC). As an investment attraction enterprise in Zhongyuan Science and Technology City and a construction unit of the Zhongyuan Aurora Laboratory, the institute is committed to the industrialization of scientific and technological achievements, guided by market demand.

 

Technical Cooperation

Resound Research Institute has established technical cooperation with numerous well-known domestic and foreign universities, research institutes, and enterprise platforms, including:
 
Tsinghua University
Lanzhou University
Zhengzhou University
Altai State Technical University of Russia
Northwestern Polytechnical University
Chinese Academy of Engineering
Henan Academy of Sciences
China Electronics Technology Group
CGN Group
Xiamen University
Henan University
National University
University of Electronic Science and Technology of China
Chinese Academy of Sciences
China Academy of Engineering Physics
China Shipbuilding Group
China Electronics Group
Henan Inspection Group
 

Research and Development Fields

* Applications of Micro-Electromechanical and Lithography Technology
* Optoelectronics and Spectroscopy Technology
* High-Power Laser and Device Preparation Technology
* Nuclear Instrument and Emergency Equipment System Applications

 

Introducing Advanced Technologies and Products

Resound Research Institute continuously introduces advanced new technologies and products in industrial application scenarios such as market supervision, public safety, environmental monitoring, and science, education, research, and production. This has led to the formation of a domestically produced high-end scientific equipment industry base that integrates design, research and
development, production, sales, and services. This base drives the iteration of downstream industry technology, enhances the transformation and industrialization level of scientific and technological achievements, and provides technological sources for innovative development.

Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512Rotary Scan Hyperspectral Imager Band Range: 900-1700nm, Resolution 640X512

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now