Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model 41 | Model 42 | Model 43 | Model 43 | Model 44 | |||
---|---|---|---|---|---|---|---|
C41.103 | C42.503 | C43.104 | C43.304 | C43.504 | C44.304 | ||
Maximum Rated Force Capacity | iN lbf |
1 220 |
5 1100 |
10 2200 |
30 6600 |
50 11000 |
30 6600 |
Force Capacity Options | N, lbf | 1 N, 5 N, 25 N, 50 N, 100 N, 250 N, 500 N, 1 kN |
1 N, 5 N, 10 N, 25 N, 50 N, 100 N, 250 N, 500 N, 1 kN |
100 N, 250 N, 500 N, 1 kN, 2.5 kN, 5 kN |
100 N, 250 N, 500 N, 1 kN, 2.5 kN, 5 kN, 10 kN, 30 kN |
100 N, 250 N, 500 N, 1 kN, 2.5 kN, 5 kN, 10 kN, 30 kN |
100 N, 250 N, 500 N, 1 kN, 2.5 kN, 5 kN, 10 kN, 30 kN |
Space Height | iN lbf |
0.2, 1, 5, 10, 20, 50, 110, 220 |
0.2, 1, 2, 5, 10, 20, 50, 110, 220, 450, 1100 |
20, 50, 110, 220, 500, 1100, 2200 |
20, 50, 110, 220, 500, 1100, 2200 |
20, 50, 110, 220, 500, 1100, 2200 |
20, 50, 110, 220, 500, 1100, 2200 |
Frame Type | Guide Columns Floor-standing/Table - top |
1 Floor - standing |
1 Table - top |
1 Table - top |
2 Table - top |
2 Table - top |
2 Floor - standing |
Test Zones | Single | Single | Single | Single | Single | Single or Dual | |
Maximum Test Speed | mm/min in/min |
3000 118 |
2000 78.7 |
2000 78.7 |
1020 40.16 |
750 30 |
1020 40.1 |
Minimum Test Speed | mm/min in/min |
0.005 0.0002 |
0.005 0.0002 |
0.005 0.0002 |
0.005 0.0002 |
0.005 0.0002 |
0.005 0.0002 |
Position Resolution | mm in |
0.000005 0.0000002 |
0.000005 0.0000002 |
0.000005 0.0000002 |
0.000006 0.00000024 |
0.000006 0.00000024 |
0.000006 0.00000024 |
Power Requirements | VAC Amp Hz phase |
200 - 230 V AC, 5 Amps, 50 / 60 Hz, 1 |
200 - 230 V AC, 8 Amps, 50 / 60 Hz, 1 |
200 - 230 V AC, 10 Amps, 50 / 60 Hz, 1 |
200 - 230 V AC, 12 Amps, 50 / 60 Hz, 1 |
200 - 230 V AC, 12 Amps, 50 / 60 Hz, 1 |
200 - 230 V AC, 12 Amps, 50 / 60 Hz, 1 |
Space Between Columns | mm in |
100 3.94" |
100 3.94" |
425 16.73 |
420 16.54 |
420 16.54 |
400 15.75 |
Vertical Test Space | Standard Length Extended Length mm in |
1100 43.31 |
800 32.3 |
1200 47.2 |
1200 47.2 |
1200 47.2 |
1100 43.31 |
1120 44.1 |
1120 44.1 |
1500 59.1 |
1500 59.1 |
1500 59.1 |
1490 58.7 |
||
Crosshead Travel | Standard Length Extended Length mm in |
900 35.4 |
650 25.6 |
1000 39.4 |
1000 39.4 |
1000 39.4 |
1000 39.4 |
950 37.4 |
1300 51.2 |
1300 51.2 |
1300 51.2 |
1300 51.2 |
1300 51.2 |
||
Frame Height | Standard Length Extended Length mm in |
1520 59.84 |
1332 52.44 |
1616 63.6 |
1752 68.97 |
1752 68.97 |
1951 76.8 |
1625 63.98 |
1825 71.85 |
1951 76.8 |
2082 82.0 |
2082 82.0 |
2251 88.6 |
C45.504 | C45 504 Wide | Model 45 | C45.305 | C45.605 | ||
---|---|---|---|---|---|---|
Maximum Rated Force Capacity | kN lbf |
50 11000 |
50 11000 |
100 22000 |
300 66000 |
600 132000 |
Force Capacity Options | N, kN | 1 kN, 2.5 kN, 5 kN, 10 kN, 20 kN, 30 kN |
1 kN, 2.5 kN, 5 kN, 10 kN, 20 kN, 30 kN |
1 kN, 2.5 kN, 5 kN, 10 kN, 20 kN, 30 kN, 50 kN, 100 kN |
150 kN, 200 kN, 300 kN |
500 kN, 600 kN |
lbf | 220, 500, 1100, 2200, 4400, 6600, 11000 |
220, 500, 1100, 2200, 4400, 6600, 11000 |
220, 500, 1100, 2200, 4400, 6600, 11000, 22000 |
33000, 44000, 66000 |
112400, 132000 | |
Frame Type | Guide Columns Floor - standing/Table - top |
2 Floor - standing |
2 Floor - standing |
2 Floor - standing |
2 Floor - standing |
2 Floor - standing |
Test Zones | Single or Dual | Single | Single or Dual | Single | Single | |
Maximum Test Speed | mm/min in/min |
750 30 |
750 29.53 |
750 30 |
750 30 |
254 10 |
Minimum Test Speed | mm/min in/min |
0.005 0.0002 |
0.005 0.0002 |
0.005 0.0002 |
0.005 0.0002 |
0.005 0.0002 |
Position Resolution | mm in |
0.000047 0.00000185 |
0.000047 0.00000185 |
0.000047 0.00000185 |
0.000049 0.00000193 |
0.000016 0.00000063 |
Power Requirements | V AC Amp Hz phase W |
200 - 230 V AC, 12 Amps, 50 / 60 Hz, 2400, 1 |
200 - 230 V AC, 12 Amps, 50 / 60 Hz, 2400, 1 |
200 - 230 V AC, 22 Amps, 50 / 60 Hz, 4400, 1 |
380 - 480 V AC, 20 Amps, 50 / 60 Hz, 5200, 3 |
380 - 480 V AC, 20 Amps, 50 / 60 Hz, 5200, 3 |
Space Between Columns | mm in |
600 23.62 |
1000 39.37 |
600 23.62 |
650 25.59 |
750 29.52 |
Vertical Test Space | Standard Length Extended Length mm in |
1220 48.0 1520 59.8 |
1520 59.81 1520 59.8 |
1220 48.0 1520 59.8 |
1540 60.63 1840 72.44 |
2000 78.74 1500 - |
Crosshead Travel | Standard Length Extended Length mm in |
1000 39.4 1300 51.18 |
- - - - |
1000 39.4 1300 51.2 |
1100 43.31 1400 55.12 |
1750 68.90 - - |
Frame Height | Standard Length Extended Length mm in |
2269 89.3 2569 101.1 |
2554 100.6 - - |
2269 89.3 2569 101.1 |
2535 99.8 2835 111.6 |
3490 137.4 - - |
Resound Research Institute continuously introduces advanced new technologies and products in industrial application scenarios such as market supervision, public safety, environmental monitoring, and science, education, research, and production. This has led to the formation of a domestically produced high-end scientific equipment industry base that integrates design, research and
development, production, sales, and services. This base drives the iteration of downstream industry technology, enhances the transformation and industrialization level of scientific and technological achievements, and provides technological sources for innovative development.