Detailed Photos
Product Description
Main Features of UT331+
- Temperature Measurement: -20°C to -70°C (±0.5°C)
- Dew - point Temperature: -78.2°C to -70°C (±1°C)
- Wet - bulb Temperature: -21.6°C to -70°C (±0.5°C)
- Humidity: 0 - 99.9%RH (±3%RH for 10% - 90%RH; ±3.5%RH for the rest)
- Resolution: Temperature: 0.1°C / Humidity: 0.1%RH
- Automatic/Manual Data Storage: 299 sets (retrievable)
- Backlight Alarm for High and Low Temperature Limits
- Maximum/Minimum Value Measurement/Data Hold
- Test Value Offset Setting: -6 to 6
- Equipped with Upper Computer Software (for real - time data viewing and exporting stored data)
- USB Power Supply: Can switch to USB power supply when a USB is inserted
Main Features of UT332+
- Temperature Measurement: -20°C ~ 70°C (±0.3°C)
- Dew - point Temperature: -78.2°C ~ 70°C (±0.8°C)
- Wet - bulb Temperature: -21.6°C ~ 70°C (±0.3°C)
- Humidity: 0 ~ 99.9%RH (±2%RH for 10% ~ 90%RH; ±2.5%RH for the rest)
- Resolution: Temperature: 0.1°C / Humidity: 0.1%RH
- Automatic/Manual Data Storage: 999 sets (retrievable)
- Backlight Alarm for High and Low Temperature Limits
- Maximum/Minimum Value Measurement/Data Hold
- Test Value Offset Setting: -6 ~ 6
- Equipped with Upper Computer Software (for real - time data viewing and exporting stored data)
- USB Power Supply: Can switch to USB power supply when a USB is inserted
Product Parameters
Model |
UT331+ |
UT332+ |
Test Temperature |
-20°C - 70°C (±0.5°C) |
-20°C - 70°C (±0.3°C) |
Dew - point Humidity |
-78.2°C - 70°C (±1°C) |
-78.2°C - 70°C (±0.8°C) |
Wet - bulb Temperature |
-21.6°C - 70°C (±0.5°C) |
-21.6°C - 70°C (±0.3°C) |
Humidity |
0 - 99%RH (±3%RH for 10% - 90%RH; ±3.5%RH for the rest) |
0 - 99%RH (±2%RH for 10% - 90%RH; ±2.5%RH for the rest) |
Resolution |
Temperature: 0.1°C, Humidity: 0.1%RH |
|
Number of Storage Groups |
299 groups |
999 groups |
Temperature Measurement |
Can switch between temperature/dew - point temperature/wet - bulb temperature |
Manual Storage |
√ |
Automatic Storage |
Automatic interval storage can be turned on/off (default off); storage interval time 0s - 60min |
Data Viewing |
Can view stored data |
Unit Setting |
Can switch between °C/°F |
Alarm Setting |
Alarm function can be turned on/off (default off); backlight alarm (upper - limit alarm red light flashes every 500ms; lower - limit alarm blue light flashes every 500ms) |
Maximum and Minimum Value Measurement |
√ |
Data Hold |
√ |
Software Data Export |
Upper - computer software can view real - time data and export data |
Automatic Shutdown |
Automatic shutdown function can be turned on/off (default on); automatic shutdown time adjustable from 5min to 60min |
Real - time Time |
Can set the system real - time time |
Offset Setting |
Can set offset values for temperature, dew - point temperature, wet - bulb temperature, and humidity (offset range: -6 - 6) |
Backlight |
Can be turned on/off (default off) |
USB Power Supply |
Insert USB to switch to USB power supply, USB voltage: |
Resound Photoelectric Technology Research Institute (LSRPTR)
Resound Photoelectric Technology Research Institute (LSRPTR), also known as Resound Research Institute, is affiliated with China Haiheng International Trade Group Co., Ltd. (CHHGC). As an investment attraction enterprise in Zhongyuan Science and Technology City and a construction unit of the Zhongyuan Aurora Laboratory, the institute is committed to the industrialization of scientific and technological achievements, guided by market demand.
Technical Cooperation
Resound Research Institute has established technical cooperation with numerous well-known domestic and foreign universities, research institutes, and enterprise platforms, including:
Tsinghua University
Lanzhou University
Zhengzhou University
Altai State Technical University of Russia
Northwestern Polytechnical University
Chinese Academy of Engineering
Henan Academy of Sciences
China Electronics Technology Group
CGN Group
Xiamen University
Henan University
National University
University of Electronic Science and Technology of China
Chinese Academy of Sciences
China Academy of Engineering Physics
China Shipbuilding Group
China Electronics Group
Henan Inspection Group
Research and Development Fields
* Applications of Micro-Electromechanical and Lithography Technology
* Optoelectronics and Spectroscopy Technology
* High-Power Laser and Device Preparation Technology
* Nuclear Instrument and Emergency Equipment System Applications
Introducing Advanced Technologies and Products
Resound Research Institute continuously introduces advanced new technologies and products in industrial application scenarios such as market supervision, public safety, environmental monitoring, and science, education, research, and production. This has led to the formation of a domestically produced high-end scientific equipment industry base that integrates design, research and
development, production, sales, and services. This base drives the iteration of downstream industry technology, enhances the transformation and industrialization level of scientific and technological achievements, and provides technological sources for innovative development.